How to choose the appropriate air conditioner capacity
Selecting the lack of air-conditioning capacity will lead to the operation of the machine too high, resulting in a waste of electricity even if it is used for a long time.
To cope with hot and sweltering summer months, many people choose to buy air conditioning to improve family life. When choosing to buy and use the air conditioner, you can choose according to the criteria: capacity, one-way or two-way machine, brand. However, the problem that everyone should consider first is to calculate the capacity of the air conditioner to match the room space.
When properly calculated, the air conditioner will run at maximum capacity and can cool the room, and the electricity cost will not be too high.
1. Select air conditioner according to capacity:
In order to calculate the conditioning capacity for the purpose of use, you need to rely on the area factor, the volume of space to be cooled. Cooling volume is the main factor used to calculate capacity.
The capacity of the conditioner is calculated in units of BTU / h . The smallest air conditioner in the market usually has a capacity of 9000 BTU / h.
BTU / h is the heat transfer capacity between two parts of the machine, not the power consumption of the machine. The power consumption of air conditioners is 9,000 BTU / h of about 0.97KW, meaning that the machine's performance is about 2.72 times. Better machine, less power, high performance can be more than 3 times. Machines with larger capacity often have higher performance.
According to the BTU / h unit usage, the air conditioner capacity in the market includes:
- 1 HP is equal to 9000 BTU
- 1.5 HP is equivalent to 12000 BTU
- 2 HP is equivalent to 18000 BTU
Formula to calculate room capacity: one cubic meter is equivalent to 200 BTU. From there we have the formula BTU = Vx200 , where V is the volume of space to install air conditioner, similar to HP = Vx200 / 9000 . Specifically:
- Room size: (3 x 4 x 3.5) m3 = 42m3, choose 1 HP conditioner
- Room size: (4 x 5 x 3.5) m3 = 70m3, choose air conditioner 1.5 HP or 2 HP.
- Room size: (5 x 6 x 3.5) m3 = 105m3, choose air conditioner 2.5 HP.
If the user calculates the capacity based on the area, he can use the formula: room height x 600x m2 / 3.3 .
For example, the room has an area of 16 m2 and a height of 3.6 m, we have calculations: 3.6 x 16 x 600 / 3.3 = 10,472 BTU. Specifically:
- Room size of 15m or less should use air conditioners with a capacity of 9000 BTU
- With an area of 15-20m2, use air conditioner with a capacity of 12,000 BTU
- The area of over 20m2 using air conditioner has a capacity of 18,000 BTU
2. Experience of selecting air conditioners according to each room type:
Air conditioner for family room
Use for common space such as living room, kitchen, plus 0.5 HP. Specifically:
- Volume of about 40 m3 choose 1.0 HP air conditioner (9000 BTU)
- Volume is about 60 m3 = 1.5 HP (12000 BTU)
- Volume of about 80 m3 = 2.0 HP (18000 BTU)
Air conditioner for cafe, restaurant
Due to the fact that there are many people at the time, with ventilation fans, they must choose the capacity for the highest load density (heat emitted by the person, outside ventilation). Specifically
- Volume of about 30 m3 = 1.0 HP (9000 BTU)
- Volume of about 45 m3 = 1.5 HP (12000 BTU)
- Volume of about 60m3 = 2.0 HP (18000 BTU)
Air conditioner for the hotel
Particularly, hotel guests who rent short-term rooms, or foreigners often require machines to quickly cool since entering the ventilation room, so the capacity is higher than the family bedroom. Specifically:
- Volume of about 35 m3 = 1.0 HP (9000 BTU)
- Volume of about 70 m3 = 2.0 HP (18000 BTU)
Air conditioner for office
Select standard office is the number of stable people equipped with working computers for each person, photocopier, fax machine, printer . If the case is few and the number of devices is not much, it can be calculated as air conditioner for family living room. Specifically:
- Volume of about 35 m3 = 1.0 Hp (9000 BTU)
- Volume of about 55 m3 = 1.5 Hp (12000 BTU)
- Volume of about 70 m3 = 2.0 Hp (18000 BTU)
Above, we have introduced ways for you to calculate the capacity to buy air conditioners. Depending on the purpose of using the room, choose the right air conditioner
Hope the above article is useful to you!
You should read it
- How to calculate the conditioning capacity in accordance with the room area
- Certain locations must be avoided when installing air conditioners
- Why does air conditioner blow out heat?
- Decode strange symbols on air-conditioning controls
- The best way to hang the air conditioner heater
- Serious mistakes when using air conditioning but many people still think right
- Structure and operating principle of air-conditioning fan
- Installation of one air conditioner for two rooms with savings?
- Top 5 reputable corrective addresses in Hanoi
- 3 common errors on air conditioner remote and how to fix it
- What to do when the air conditioner generates noise?
- Things to consider using air conditioner for babies in the cold season
Maybe you are interested
No More Ransom - the flag of the war against ransomware Determine the secret location of TR-3B UFO triangle on Google Earth? Early in the morning, Venus and Jupiter will meet in the sky, don't miss this magical, rare moment! Google Maps detects 8 strange bases of aliens? Is life on Mars captured? UFOs and aliens 'found' on Red planet Discovering 'alien antenna' on the Moon?