Learn the most common Mitsubishi air conditioner fault codes

Don't miss the TipsMake.com article if you want to know more about Mitsubishi air conditioner and air conditioning codes.

Mitsubishi air conditioner is a product of Mitsubishi brand, Japan. Like many current regulators, Mitsubishi air conditioners may also experience some errors during operation. The TipsMake.com article will help you find out more about the most common Mitsubishi air conditioning and air conditioning codes .

Air conditioner error code, Mitsubishi Electric air conditioner

  1. 1102  : Abnormal discharge temperature
  2. 4330  : Error of preheating preheating radiator
  3. 1111  : Saturated temperature sensor error
  4. 4340  : Preliminary overload protection error
  5. 1112  : Temperature sensor error, low pressure, low saturation level
  6. 4350  : Preliminary overcurrent protection error
  7. 1113  : Temperature sensor error, abnormal temperature, liquid saturation level
  8. 5101  : Air input error
  9. 1143  : Lack of cold, weak cold
  10. 5102  : Fluid tube error
  11. 1202  : Preliminary discharge temperature error
  12. 5103  : Error of gas tube
  13. 1205  : Preliminary heart tube temperature sensor error
  14. 5104  : Liquid temperature sensor error
  15. 1211  : Low saturation pressure error.
  16. 5105  : Loose duct error
  17. 1214  : Error of circuit, THHS sensor.
  18. 5106  : Environmental temperature error
  19. 1216  : Preliminary cooling coil sensor error.
  20. 5107  : Error of power cord jack
  21. 1217  : Thermal coil sensor error.
  22. 5108  : Unplugged error
  23. 1219  : Fault coil sensor error.
  24. 5109  : Error of CS circuit
  25. 1221  : Environmental temperature sensor error
  26. 5110  : Radiator control panel error
  27. 1301  : Abnormal low pressure error.
  28. 5112  : Air compressor temperature error
  29. 1368  : Unusual liquid pressure error.
  30. 5201  : Error of pressure sensor
  31. 1370  : Intermediate pressure error
  32. 5203  : Error of intermediate pressure sensor
  33. 1402  : Preliminary high pressure error
  34. 5301  : Error of circuit, IAC sensor
  35. 1500  : Overload cold error
  36. 6600  : Duplicate address error
  37. 1505  : Suction pressure error
  38. 6602  : Hardware error of transmission processing
  39. 1600  : Preliminary cold overload error
  40. 6603  : Error of BUS transmission circuit
  41. 1605  : Pre-suction pressure temperature error
  42. 6606  : Error information
  43. 1607 : CS cold block error
  44. 6607 : Error without ACK
  45. 2500 : Water leak error
  46. 6608 : Error without response
  47. 2502 : Buoy pump error
  48. 6831 : Error not receiving MA information
  49. 2503 : Water sensor error
  50. 6832 : Error not receiving MA information
  51. 4103 : Reverse phase error
  52. 6833 : Error sending MA information
  53. 4115 : Power signal synchronization error
  54. 6834 : Error receiving MA information
  55. 4116 : Fan speed error
  56. 7100 : Total voltage error
  57. 4200 : Error of circuit, VDC sensor
  58. 7101 : Error of voltage code
  59. 4220 : BUS voltage error
  60. 7102 : Connection errors
  61. 4230 : Error of the hot dispenser of radiator control
  62. 7105 : Error setting address
  63. 4240 : Error of overload protection
  64. 7106 : Characteristics installation error
  65. 4250 : Overcurrent, voltage error
  66. 7107 : Error installing sub-branch
  67. 4260 : Cooling fan error
  68. 7111 : Remote control sensor error
  69. 4300 : Circuit fault, VDC sensor
  70. 7130 : The connection error is not the same for the cooler
  71. 4320 : Initial bus voltage error

 

Error codes for Mitsubishi Heavy cylinders and air conditioners

Mitsubishi Heavy air conditioners often report flashing lights. Please base on the error message below to determine the condition of the air conditioner and find a suitable solution:

  1. Flash light 1 time : The indoor unit is damaged, the sensor is broken, the connection is poor
  2. Flashes twice : Temperature sensor error
  3. Flashes 5 times : Error of voltage filter, outdoor circuit board
  4. Flash lights 6 times : Faulty cold motor motor failure or bad connection.
  5. Flashes continuously but only once : Sensor error on the outdoor unit, the outdoor unit board has trouble.
  6. The lamp flashes continuously for 4 times : Compression line sensor does not work well.
  7. Timer light flashes once : Blocked muscle, Power Transtor is touched
  8. Timer light blinks twice : Error of outdoor unit, block
  9. Timer light blinks 3 times : Residual gas or components are touched
  10. Timer light blinks 4 times : Power Transistor error
  11. Timer light blinks 5 times : Lack of gas, unopened gas valve, sensor failure path.
  12. Timer light blinks 6 times : Signal line fault, indoor unit board : 
  13. Timer light blinks 7 times : Error of outdoor unit fan, signal line, broken board.

Hope that the air conditioner error code and Mitsubishi air conditioner : will be useful to you. For more detailed advice on information and usage of air conditioner and Mitsubishi air conditioner, please contact TipsMake.com.

4.1 ★ | 164 Vote