Error code table on Aqua air conditioners: Causes and solutions
AQUA is a line of air conditioners that is no longer strange to many users. However, after a period of use, the air conditioner will appear a few errors that make you feel quite uncomfortable and worried. Don't worry, the following article will provide you with information about the cause and instructions on how to fix the errors on the AQUA air conditioner line. Let's see together.
1. Causes of errors on AQUA . air conditioners
- AQUA air conditioner is short of gas or out of gas.
- The indoor unit or outdoor unit of the machine is too dirty to prevent the machine from dissipating heat.
- Damaged outdoor unit fan or damaged indoor unit fan, also known as dead fan.
- The power cord, signal wire of the air conditioner is broken or flickered.
- The cause comes from the failure of the outdoor unit, the block does not run, the block eats the current.
- The air conditioner is damp or the main circuit is damaged causing the error.
- Damage to the outdoor unit or indoor unit sensor prevents the unit from measuring the temperature.
- Maybe you have used the wrong remote control, used the wrong function, wrong mode, causing the machine to have an error.
- Slow machine rewind speed, prolonged standby or too early can also cause errors.
- The machine appeared error due to failure of pressure valve, failure of one-way valve.
Some causes of Aqua air conditioner failure
2. Error code on AQUA Inverter air conditioner series
System damage
Error code: E7.
This error code is known as a connection error between the outdoor unit and the indoor unit.
The cause of error E7 is due to loose connection of the compressor's wire, damaged control circuit or damage to the indoor unit.
Damaged indoor unit
Error code | Error description | Reason |
E1 | The room temperature sensor is faulty. | The temperature sensor connection is loose. The temperature sensor is damaged. The indoor unit control circuit is broken. |
E2 | The heat exchanger sensor is faulty. | The temperature sensor connection is loose. The temperature sensor is damaged. The indoor unit control circuit is broken. |
E4 | Control circuit error. | The indoor unit control circuit is broken. |
E14 | The indoor unit fan motor is faulty. | The fan motor coil is broken. Protect fan motor from overheating. The wire connecting the fan motor is broken. The indoor unit control circuit is broken. |
Damaged outdoor unit
Error code | Error description | Reason |
F1 | Module circuit error. | The module circuit is damaged. |
F2 | Compressor is overcurrent. | Compressor is damaged. The module circuit is damaged. |
F3 | Connection error of the module circuit and the main control circuit of the line array. | The connection between the main control circuit and the module circuit is loose. The main control circuit of the outdoor unit is broken. The main unit module circuit is loose. |
F4 | Output overheat protection. | Electronic throttle valve is damaged. The temperature sensor is damaged. The main control circuit of the outdoor unit is broken. |
F6 | Ambient temperature sensor error. | The temperature sensor is damaged. |
F7 | Input temperature sensor error. | The temperature sensor is damaged. |
F8 | The outdoor unit fan motor is faulty. | The outdoor unit fan motor coil is broken. The power cord connecting the motor wire is broken. The main control circuit of the outdoor unit is broken. |
F11 | Compressor error. | Compressor is damaged. |
F12 | Error in the main control circuit of the outdoor unit. | The main control circuit of the outdoor unit is broken. |
F18 | The supply voltage is too high or too low. | The power supply is not stable. The main control circuit of the outdoor unit is broken. The main unit module circuit is loose. |
F21 | Defrost temperature sensor error. (Only in two-way air conditioners). | The temperature sensor connection is broken. The temperature sensor is damaged. The main control circuit of the outdoor unit is broken. |
F25 | Output temperature sensor error. | The temperature sensor is damaged. |
3. Error code on regular AQUA air conditioners
Below is a table of error codes on the Aqua series usually for you:
Error code | Error description | Reason |
F1 | The temperature sensor in the room is faulty. | Sensor open circuit or short circuit. Connection failure at connection/open circuit at fold position. The connection board is broken. |
F2 | The indoor unit exchanger sensor is faulty. | Compressor is damaged. The module circuit is damaged. |
H1 | In the state of defrosting (for 2-way machines). | This is normal operation, 'H1' will not be displayed after defrosting is finished. |
H6 | The indoor unit motor is faulty. | The fan motor is damaged. This situation occurs when the fan motor runs too slowly, to avoid activating the motor self-protection mode, the machine will stop and display the lock. Poor connection of local contacts. |
C5 | The OTP box is faulty. | The PCB cover is damaged. PCB is damaged. |
4. Other error codes on Aqua air conditioner
You can also refer to other error codes on Aqua air conditioners in the table below:
Error code | Error description | Reason |
E5 | Serial communication signal reception is faulty. | Circuit is damaged. |
E6 | Serial communication signal transmission error. | Circuit is damaged. |
E7 | The indoor unit power is too low. | Dirty indoor unit, lack of capacity. |
E8 | Indoor unit address setting is mirrored. | Circuit is damaged. |
E9 | The remote controller setup is mirrored. | Circuit is damaged. |
E10 | Serial communication signal transmission error. | Circuit is damaged. |
E11 | Duplicate main unit concurrent multi control action. | Circuit is damaged. Controller is faulty. |
E15 | Indoor unit power too high | The machine temperature is high. |
E16 | There are no connected units in the house. | There is a problem with the power cord connection. |
E17 | Serial communication signal reception is faulty. | Circuit is damaged. |
E18 | Communication failed with main module. | There is a problem with the power cord connection. |
E20 | Serial communication signal transmission error. | Circuit is damaged. |
E31 | Setting the indoor unit group Aqua air conditioner reported an error. | Circuit is damaged. |
F12 | Aqua air conditioner reports EEPROM error in the house. | Circuit is damaged. |
F28 | Outdoor EEPROM error. | Circuit is damaged. |
F29 | Outdoor EEPROM error. | Circuit is damaged. |
F31 | Outdoor EEPROM error. | Circuit is damaged. |
P01 | Float conversion failed. | Circuit is damaged. |
P03 | Open phase detection, AC power trouble. | There is a problem with the power cord connection. |
P10 | Discharge temperature is faulty. | The temperature is too low or too high. |
P15 | The 4-way valve is locked. | The 4-way valve is locked. |
P19 | High cooling load. | Poor radiator. |
P20 | The outdoor fan has a problem. | The outdoor unit fan is damaged. |
P22 | Compressor has problem (HIC PCB). | The machine block is broken. |
P26 | Trouble from the compressor (MDC). | The machine block is broken. |
P29 | Simultaneous effect multi-control trouble. | Circuit is damaged. |
P31 | Compressed air overload. | The machine block is broken. Engine valve is damaged. |
L01 | Indoor/outdoor style units are not suitable. | Circuit is damaged. |
L02 | Duplicate units in the control group. | Circuit is damaged. |
L03 | The outdoor unit address is copied. | Circuit is damaged. |
L04 | Group of connection wires for independent indoor units. | There is a problem with the power cord connection. |
L07 | Address not set or group not set. | Circuit is damaged. |
L08 | The indoor unit capacity is not set. | The indoor unit control circuit is broken. |
L09 | Outdoor power unit not set or set. | The connection between the main control circuit and the module circuit is loose. The main control circuit of the outdoor unit is broken. |
L11 | Indoor unit installation error. | The control circuit is broken. |
L13 | Connection failed. | Circuit is damaged. |
5. How to fix errors on Aqua air conditioners
When your air conditioner encounters the errors listed above, you should contact the service center so that it can be repaired as soon as possible.
Please contact the service center for support as soon as possible when Aqua air conditioner has a problem
Above is the cause and how to fix the error code on Aqua air conditioners. Thanks for watching!
You should read it
- How to use air conditioner control, Aqua air conditioner accurately, save electricity
- What types of air conditioner are available today?
- Samsung Air Conditioning, Air Conditioning Code: How to check and diagnose
- Things to keep in mind when buying used air conditioners
- Compare air conditioners
- The common side by side fridge size
- What is the best way to buy air conditioner using gas?
- Popular modes of use on air conditioners
- Portable air conditioners: How to buy the best one for your home
- How to check when buying and assembling air conditioners
- Learn the structure, installation and use of air conditioners
- Learn the technology of air filtration on air conditioners today
Maybe you are interested
Top best electronic circuit drawing software
The world's first circuit board that can be dissolved in water
Top 5 best circuit drawing software 2021
Top best electronic circuit design software
How to Wire a Breaker Circuit
Why is the Apple printed circuit board black while most other manufacturers are green?